Products
-
IEC60502 Standard Low Voltage ABC Aerial Bundled Cable
The IEC 60502 standard specifies characteristics such as insulation types, conductor materials and cable construction.
IEC 60502-1 This standard specifies that the maximum voltage for extruded insulated power cables shall be 1 kV (Um = 1.2 kV) or 3 kV (Um = 3.6 kV). -
ASTM Standard PVC Insulated LV Power Cable
Used for control and power applications in chemical plants, , industrial plants, utility substations and generating stations, residential and commercial buildings
-
Twin Core Double XLPO PV Solar Cable
Twin Core Double XLPO PV Solar Cable is permitted to be installed in cable trays, wire ways, conduits, etc.
-
ASTM UL XLPE XHHW XHHW-2 Copper Wire High Heat-resistant Water-resistant
XHHW wire stands for “XLPE (cross-linked polyethylene) High Heat-resistant Water-resistant.” XHHW cable is a designation for a specific insulation material, temperature rating, and condition of use (suitable for wet locations) for electrical wire and cable.
-
SANS Standard 3.8-6.6kV-XLPE Insulated MV Middle Voltage Power Cable
SANS Standard 3.8-6.6kV XLPE-insulated medium-voltage power cables are manufactured in accordance with South African National Standards.
Copper or Aluminium Conductors, single or 3 Core, Armoured or Unarmoured, bedded and served in PVC or non-halogenated material, Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards -
60227 IEC 06 RV 300/500V Electrical Building Wire Single Core Non Sheathed 70℃
Single core 70℃ flexible conductor unsheathed cable for internal wiring
-
SANS 1507 CNE Concentric Cable
SANS 1507 CNE concentric cables conform to South African standards and are specifically designed for reliable domestic service connections.
Circular stranded hard-drawn copper phase conductor, XLPE insulated with concentrically arranged bare earth conductors. Polyethylene sheathed 600/1000V house service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS 1507-6. -
SANS1418 Standard Low Voltage ABC Aerial Bundled Cable
SANS 1418 is the national standard for overhead bundled cables (ABC) systems in South Africa’s overhead distribution networks, specifying structural and performance requirements.
Cables for overhead power distribution systems mainly for public distribution. Outdoor installation in overhead lines tightened between supports, lines attached to façades. Excellent resistance to external agents. -
ASTM standard XLPE Insulated LV Power Cable
As three- or four-conductor power cables rated 600 volts, 90 deg. C. in dry or wet locations.
-
IEC BS Standard 12-20kV-XLPE Insulated PVC sheathed MV Power Cable
Suitable for energy networks such as power stations. For installation in ducts, underground and outdoor.
There’s huge variations in construction, standards and the materials used – specifying the correct MV cable for a project is a matter of balancing the performance requirements, installation demands, and environmental challenges, and then ensuring cable, industry, and regulatory compliance. With the International Electrotechnical Commission (IEC) defining Medium Voltage cables as having a voltage rating of above 1kV up to 100kV that’s a broad voltage range to consider. It’s more common to think as we do in terms of 3.3kV to 35kV, before it becomes high voltage. We can support cable specifications in all voltages.
-
BS 6004 6241Y 6242Y 6243Y Cable PVC Insulated And Sheathed Flat Twin And Earth Wire
6241Y 6242Y 6243Y Cable PVC Insulated And PVC Sheathed Flat Twin And Earth Wire with bare circuit protective conductor CPC.
-
SANS Standard 6.35-11kV-XLPE Insulated Middle Voltage Power Cable
11kV medium voltage electric power cable with copper conductors, semi-conductive conductor screen, XLPE insulation, semi-conductive insulation screen, copper tape metallic screen, PVC bedding, Aluminium wire armour (AWA) and PVC outer sheath. The cable is suitable for Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards