Medium Voltage Power Cable
-
IEC/BS Standard 6-10kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS 6-10kV XLPE-insulated medium-voltage (MV) power cables comply with standards such as IEC 60502-2 for XLPE-insulated cables and BS 6622 for armoured cables.
The conductors utilise XLPE to achieve excellent electrical insulation and thermal insulation. -
AS/NZS standard 3.8-6.6kV-XLPE Insulated MV Power Cable
3.8-6.6kV XLPE-insulated medium-voltage power cables are suitable for distribution or secondary transmission networks, typically serving as the primary power supply for commercial, industrial, and urban residential networks. They are applicable to systems with high fault currents rated up to 10kA for 1 second. Structures with higher rated fault current capacities may be provided upon request.
-
IEC/BS Standard 8.7-15kV-XLPE Insulated MV Middle Voltage Power Cable
8.7/15kV XLPE-insulated medium-voltage (MV) power cables are specifically designed for power transmission and distribution networks.
This medium-voltage cable complies with the International Electrotechnical Commission (IEC) standards and British Standards (BS).
8.7/15kV, indicating suitability for systems with a maximum operating voltage of 15kV. 15kV is a voltage commonly specified for equipment cables, including robust Mining equipment cables, manufactured in accordance with IEC 60502-2, but is also associated with British standard armoured cables. Whilst mining cables may be sheathed in a robust Rubber to provide abrasion resistance, especially for trailing applications, the BS6622 and BS7835 standard cables are instead sheathed in PVC or LSZH materials, with mechanical protection provided from a layer of steel wire armouring. -
AS/NZS standard 6.35-11kV-XLPE Insulated MV Power Cable
6.35-11kV XLPE-insulated medium-voltage power cables are suitable for distribution or secondary transmission networks, typically serving as the primary power supply for commercial, industrial, and urban residential networks.
-
IEC/BS Standard 12.7-22kV-XLPE Insulated MV Middle Voltage Power Cable
Suitable for energy networks such as power stations. For installation in ducts, underground and outdoor.
The cables made to BS6622 and BS7835 are generally supplied with Copper conductors with Class 2 rigid stranding. Single core cables have aluminium wire armour (AWA) to prevent induced current in the armour, whilst the multicore cables have steel wire armour (SWA) providing the mechanical protection. These are round wires that provide over 90% coverage.
Please note: Red outer sheath can be prone to fading when exposed to UV rays.
-
AS/NZS standard 12.7-22kV-XLPE Insulated MV Power Cable
12.7-22kV XLPE-insulated medium-voltage power cables are suitable for distribution or secondary transmission networks, typically serving as the primary power supply for commercial, industrial, and urban residential networks. Featuring an LSZH sheath material, they are suitable for indoor, public areas, or other environments requiring fire safety considerations.
-
IEC/BS Standard 18-30kV-XLPE Insulated MV Middle Voltage Power Cable
18/30kV XLPE-insulated medium-voltage (MV) power cables are specifically designed for distribution applications.
Cross-linked polyethylene provides the cables with excellent electrical insulation and thermal insulation. -
AS/NZS standard 19-33kV-XLPE Insulated MV Power Cable
19-33kV XLPE-insulated medium-voltage power cables are suitable for fixed installation in power supply networks within both indoor and outdoor environments. They may be installed in cable ducts, on cable trays, or directly buried underground.
-
IEC/BS Standard 19-33kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS Standard 19/33kV XLPE-insulated MV power cables comply with International Electrotechnical Commission (IEC) and British Standards (BS) specifications.
IEC 60502-2: Specifies the construction, dimensions and tests for extruded insulated power cables up to 30 kV.
BS 6622: Applies to thermoset insulated armoured cables for voltages of 19/33 kV. -
IEC BS Standard 12-20kV-XLPE Insulated PVC sheathed MV Power Cable
Suitable for energy networks such as power stations. For installation in ducts, underground and outdoor.
There’s huge variations in construction, standards and the materials used – specifying the correct MV cable for a project is a matter of balancing the performance requirements, installation demands, and environmental challenges, and then ensuring cable, industry, and regulatory compliance. With the International Electrotechnical Commission (IEC) defining Medium Voltage cables as having a voltage rating of above 1kV up to 100kV that’s a broad voltage range to consider. It’s more common to think as we do in terms of 3.3kV to 35kV, before it becomes high voltage. We can support cable specifications in all voltages.
-
SANS Standard 3.8-6.6kV-XLPE Insulated MV Middle Voltage Power Cable
SANS Standard 3.8-6.6kV XLPE-insulated medium-voltage power cables are manufactured in accordance with South African National Standards.
Copper or Aluminium Conductors, single or 3 Core, Armoured or Unarmoured, bedded and served in PVC or non-halogenated material, Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards -
SANS Standard 6.35-11kV-XLPE Insulated Middle Voltage Power Cable
11kV medium voltage electric power cable with copper conductors, semi-conductive conductor screen, XLPE insulation, semi-conductive insulation screen, copper tape metallic screen, PVC bedding, Aluminium wire armour (AWA) and PVC outer sheath. The cable is suitable for Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards